$50 Gets Your Package Globally – For Free
HVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance Services
HVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance ServicesHVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance ServicesHVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance ServicesHVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance ServicesHVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance ServicesHVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance ServicesHVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance ServicesHVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance ServicesHVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance Services

HVAC Refrigerant Recovery Machine - 3/4HP Oil-less Compressor for Automotive, Household & Commercial AC Systems - Freon Liquid & Vapor Recovery Tool Kit - Perfect for HVAC Technicians, Auto Repair Shops & AC Maintenance Services

$192.49 $349.99 -45%
Color:
Orange
Gray
Blue

Delivery & Return:Free shipping on all orders over $50

Estimated Delivery:7-15 days international

People:24 people viewing this product right now!

Easy Returns:Enjoy hassle-free returns within 30 days!

Payment:Secure checkout

SKU:41975417

Guranteed safe checkout
amex
paypal
discover
mastercard
visa

Product Description

YOU MAY IN NEED OF IT When refrigerant needs to be discharged from the refrigeration equipment for maintenance or dismantling, you must recover the refrigerant to avoid atmospheric pollution and also for reusing the refrigerant.High configuration with high performance, featured with overvoltage protection and overload protection, three modes of operation, ADAFIRST refrigerant recovery unit is widely used for recycling Category III, IV, V refrigerants in auto household and commercial air conditioning systems, refrigerators, freezers, dehumidifiers, heat pump units and other refrigerable equipments. SET INCLUDES Refrigerant Recovery Machine Kit Refrigerant Recovery Machine x 1Filter Drier x 1Connecting Hose x 1Power Supply Cord x 1Spare O-ring and Filter Screen x 1Detailed Instruction x 1 High Configuration and High Performance High-quality oil-free compressor: 110-120V 60HZ one piston style, 3/4HP motor with 1750rpm motor speed oil-free compressor, no oil change trouble and cost, reduce the risk of oil pollutionOptimized cooling system: The front of the recovery unit is equipped with a large air intake and a large air cooling condenser, and the rear side is equipped with a large fan. Optimized cross-flow layout design ensures maximum cooling performance, faster recovery speed to shorter cycle timeHigh quality capacitors: High quality starting capacitor and running capacitor help to start quickly and run smoothly, improve motor performance and reduce energy consumption.Clear pressure gauge: Blue low pressure gauge for refrigerant recovery machine input pressure, red high pressure gauge for recovery device outlet pressure.Compact and portable: The housing is compact and sturdy (relatively light, only 14kg), making it easy to carry or store, easy to transport to facilitate multi-scenario applicationsSpecial filter device: Special filter dryer to filter moisture while recovering refrigerant, and filter screen to filter possible impurities, to protect the internal compressor. Notice each type of refrigerant must have its own filter dryer. The filter dryer needs to be replaced frequently and the filter screen should be washed frequently to keep it clean Dual Protection Mechanism Overpressure protection mechanism: There is a high pressure cut-off switch inside the refrigerant recovery machine. When the internal pressure is higher than 38.5bar, the compressor will automatically shut down. Please reduce the internal pressure, high pressure switch will reset and the compressor will restart automatically.Overload protection mechanism: There is an overload cut-off switch outside the refrigerant recovery machine. If the overload protector pops out, please restart the circuit breaker manually after 5 minutes Three Operation Modes Refrigerant (vapor and liquid) recovery mode & Self-cleaning mode operation Required device: refrigerant recovery tank, electric scale, refrigerant recovery machine, AC manifold gauge, refrigerant device, safety goggles and protective gloves 1. Turn the metal knob on the refrigerant recycling machine to 1, turn off the power switch, and connect the power supply cord2. Connect all the devices according to the connection diagram in the instruction manual3. Start the power switch of the refrigerant recovery machine, open the liquid valve of the refrigerant recovery tank and AC manifold gauge4. Slowly turn the metal knob to "2" for quick recovery. Always pay attention to the low pressure gauge value, do not exceed 26bar. And also always pay attention to the refrigerant recovery tank electronic scale, to ensure that it does not exceed 80% of the maximum capacity of the recovery tank 5. After all the refrigerant recycled, turn the metal knob of the refrigerant recovery unit to "3" and start the self-cleaning mode. The refrigerant recovery device must be self-cleaning after each use to ensure that no refrigerant remains. Otherwise, the remaining refrigerant may expand and damage components. It is recommended to completely vacuum the refrigerant and clean it with dry nitrogen when storing it for a long time. Liquid refrigerant push/pull mode Required device: refrigerant recovery tank, electric scale, refrigerant recovery machine, refrigerant device, safety goggles and protective glovesWhen the amount of liquid refrigerant to be recovered is greater than 10kgs, you are advised to use the push/pull mode to speed up the process. Please follow the detailed instructions.After the liquid recovery is completed, the conventional refrigerant (vapor and liquid) recovery mode is adopted for the vapor refrigerant. ADAFIRST Refrigerant Recovery Machine ADAFIRST 3 Way AC R1234yf Manifold Gauge Set ADAFIRST 4 Way AC Manifold Gauge Set ADAFIRST 3 Way AC Manifold Gauge Set ADAFIRST 3 Way AC Manifold Gauge Set ADAFIRST R134a Charging Hose with Gauge Add to Cart Add to Cart Add to Cart Add to Cart Buying Options Buying Options Customer Reviews 4.6 out of 5 stars 12 4.0 out of 5 stars 26 4.3 out of 5 stars 22 4.2 out of 5 stars 35 3.5 out of 5 stars 40 3.8 out of 5 stars 46 Price $349.99$349.99 $52.99$52.99 $59.99$59.99 $36.99$36.99 — no data — no data Function Refrigerant Recovery Auxiliary AC evacuation (vacuum) & diagnostic check, refrigerant charging & recovery Auxiliary AC evacuation (vacuum) & diagnostic check, refrigerant charging & recovery Auxiliary AC evacuation (vacuum) & diagnostic check, refrigerant charging & recovery Auxiliary AC evacuation (vacuum) & diagnostic check, refrigerant charging & recovery Auxiliary AC evacuation (vacuum) & diagnostic check, refrigerant charging

Product Features

High Configuration Performance Recovery machine HVAC is equipped with 110-120 V 60 HZ single piston, 3/4 HP 1750 rpm motor, oil-free air-cooled compressor and MAX. recovery rate reaches 9 kg/min (Category V refrigerants in push-pull mode). High-quality starting and running capacitor help to start quickly and run smoothly, improve motor performance and reduce energy consumption. Large condenser and fan, optimized cross-flow layout design ensure maximum cooling performance and faster recovery rate

Wide Application The AC refrigerant recovery machine can be widely used to recover liquid and vapor refrigerant such as Category III, IV, V refrigerants, which widely used in automotive household and commercial air conditioning systems, refrigerators, freezers, dehumidifiers, heat pump units and other refrigerable equipments. Meanwhile, this HVAC refrigerant recovery tool has compact and strong housing with light weight (only 14 kgs), easy to transport to facilitate multi-scenario applications

Three Operation Modes Portable freon recovery equipment has three modes of operation refrigerant recovery mode (conventional recovery of vapor and liquid refrigerant), system push and pull mode (rapid recovery of more than 10 kgs liquid refrigerant), and system self-purge mode (remove residual refrigerant). The three operation modes can be realized through the connection of different devices and the metal operation button modes (RECOVER SLOW, RECOVER FAST, PURGE, OFF) on the operation panel

High Pressure and Overload Protection The recovery device input pressure shall not exceed 26 bar. When the internal pressure is higher than 38.5 bar, the internal high pressure shut-off switch will be triggered and the compressor will automatically power off. Please reduce the internal pressure until the high pressure shut-off switch resets automatically and the compressor will restart. If overload protector button on the panel pops out during use, please manually reset it after 5 minutes

After-sale Company First of all, welcome to the ADAFIRST store. Thank you for your trust and choice of ADAFIRST. We are committed to providing customers with satisfied product and quality service, customer satisfaction is our pursuit. To prevent delaying your work, please check the completeness and functional performance of your purchase as soon as you receive it. If you have any questions, please come to us and we will be at your service

Customer Reviews

****** - Verified Buyer

Good equipment