Delivery & Return:Free shipping on all orders over $50
Estimated Delivery:7-15 days international
People:10 people viewing this product right now!
Easy Returns:Enjoy hassle-free returns within 30 days!
Payment:Secure checkout
SKU:82420439
3/4HP Single Cylinder Refrigerant Recovery Machine 110V-120V 60Hz, for Both Liquid and Vapor Refrigerant FEATURES: 1. Automatic shut-off switch and reliable overload protection for safe operation 2. Multiple refrigerants matching for wide applications 3. Excellent recovery and push/pull method for high-efficient performance 4. Superior self-purge technology for longer service life 5. Durable oil-less compressor and compact design for easy carrying Specifications Power: 110V-120V, 60Hz (Single cylinder) Motor: 3/4HP, 1750RPM Maximal current draw: 10A Compressor: Single-cylinder, oil-less, air-cooled, piston High pressure shut-off: 38.5bar / 3850kPa (558psi) Operating temperature: 0℃~40℃ / 32℉~104℉ Dimension: 400mm*250mm*360mm Weight: 13.5KG Recovery Machine Features Oil-free Compressor There is no lubricating oil to pollute recovered refrigerants with the oil-free compressor, so you can recover most refrigerants by one freon recycling unit, just replacing the filter drier. Accurate Pressure Gauge The low pressure gauge shows the input pressure of the refrigerant recovery machine, the high pressure gauge shows the output pressure of the freon recycling unit. Air-cooled Condenser The recovery machine is installed with a large condenser and a fan, which can ensure the maximum cooling performance, short cycle time and fast recovery speed. RECOVERY & SELF-PURGE METHODS · Recovery method is for recycling liquid and vapor refrigerant with slow and fast modes. · Self-purge method is for checking if there is refrigerant left or remained in the machine to avoid expanding or damaging the components. LIQUID PUSH & PULL METHOD · If the liquid refrigerant recovery is more than 10kg, it is recommended to use the push / pull method for faster process. WARNING!!! 1. Read all safety instructions carefully before use. 2. Only qualified technicians could operate this recovery unit. 3. Always wear safety goggles and protective gloves during the work. Avoid gas or liquid refrigerant. 4. Do not overfill the recovery tank. A scale is needed to avoid overfilling the recovery tank. The tank is full at 80% capacity. 5. The inlet pressure must not exceed 26bar. 6. This equipment should be used in locations with mechanical ventilation or the equipment should be located at least 50cm above the floor. 7. Do not use this equipment in the vicinity of spilled or open containers of gasoline. 8. If needed, use a 3-wire extension cord 12AWG minimum and shorter than 7.5m, with reliable grounding. WIDE APPLICATIONS · The freon recycling unit fits for all kinds of Category III, IV, V refrigerants, such as R12, R134a, R401C, R406A, R500, R22, R401A, R401B, R402B, R407C, R407D, R408A, R409A, R411A, R411B, R412A, R502, R509, R402A, R404A, R407A, R407B, R410A, R507. · The machine is widely applied in automotive, household and commercial apliances, like air conditioner, freezer, heat pump unit, etc. But please note it is not allowed for explosive, flammable or corrosive refrigerants.
High-efficient Recovery The refrigerant recovery machine is equipped with a 110V-120V 60 Hz single-cylinder oil-less compressor, it has a powerful recovery speed of 3/4 HP, which can recover vapor and liquid refrigerants quickly
Overload & Safety Protection The refrigerant recycling machine comes with a built-in intake pressure gauge (blue) and a discharge pressure gauge (red), which have clear scale for easy observation at any time. When the internal pressure is above 558 psi, it will shut down automatically for safe operation guarantee. Inversely, the machine will reset automatically. The unit is installed with an overload protector, if popping, the breaker switch will reposition after 5 minutes
Self-purge Function The refrigerant recovery unit has a purge switch, which can help clean up the residual refrigerants in the recovery kit and avoid it from damages caused by the residual refrigerants inside. The filter drier comes with the machine can remove moisture and liquid substance in the air, the filter is replaceable
Overall Structure The refrigerant recovery machine mainly includes a 110V-120V 60 Hz single cylinder, 3/4 HP powerful motor and oil-less compressor. The sturdy body and good-quality components ensure the long service life, and the compact design with ergonomic handle makes the machine easy to transport and carry. The big condenser and fan with upgraded cross-flow layout design ensure the superior cooling performance, shorter cycle time and faster recovery speed
Wide Application The freon recycling unit fits for all kinds of Category III, IV, V refrigerants, such as R12, R134a, R401C, R406A, R500, R22, R401A, R401B, R402B, R407C, R407D, R408A, R409A, R411A, R411B, R412A, R502, R509, R402A, R404A, R407A, R407B, R410A, R507. The machine is widely compatible with automotive, household and commercial apliances, like air conditioner, freezer, heat pump unit, etc. But please note it is not allowed for explosive, flammable or corrosive refrigerants
High quality. Strong machine does everything it is supposed to well. Be sure to always use a filter with it to protect it. Has a good purge fucntion.